Clearance to Combustibles
| JOYCE | Boiler (mm) | Non-Boiler (mm) |
|---|---|---|
| from Front | 915 | 915 |
| from Back | 380 | 635 |
| from Sides | 500 | 500 |
| from Flue Pipe | 460 | 610 |
| from Corners | 300 | 300 |
| YEATS | Boiler (mm) | Non-Boiler (mm) |
|---|---|---|
| from Front | 915 | 915 |
| from Back | 420 | 635 |
| from Sides | 510 | 510 |
| from Flue Pipe | 460 | 610 |
| from Corners | 330 | 330 |
| WILDE | Boiler (mm) | Non-Boiler (mm) |
|---|---|---|
| from Front | 1220 | 1220 |
| from Back | 420 | 635 |
| from Sides | 635 | 635 |
| from Flue Pipe | 460 | 610 |
| from Corners | 345 | 345 |
| from Horizontal Connector to Ceiling | 460 | 460 |
| BECKETT | Boiler (mm) | Non-Boiler (mm) |
|---|---|---|
| from Front | 1220 | 1220 |
| from Back | 420 | 635 |
| from Sides | 635 | 635 |
| from Flue Pipe | 460 | 610 |
| from Corners | 345 | 345 |
| from Horizontal Connector to Ceiling | 460 | 460 |